HRV glossary

Short definitions of the terms you meet in HRV apps and research. Each links to a fuller explanation.

See every HRV parameter grouped by family Units, formulas and recording lengths side by side, from RMSSD to DFA α1.

A

Approximate entropy measured in nats
The older cousin of sample entropy, with no unit: a regularity measure that counts each run of beats as matching itself, which biases it towards low values on short recordings.
Artifact
An error in a heartbeat recording, such as a missed, extra or mistimed beat, often caused by movement or poor sensor contact. Artifacts can badly distort HRV numbers.
Autonomic nervous system
The part of the nervous system that runs the body without conscious control, including heart rate. HRV mostly reflects how it adjusts the heart from moment to moment.

B

Baevsky stress index measured in ratio
A number built from the histogram of heartbeat intervals, with no unit. It rises as the rhythm gets steadier and less variable, which Baevsky read as strain on the body's regulation.
Baroreflex
The reflex that steadies blood pressure from beat to beat by changing heart rate. Its built-in delay makes heart rate rise and fall about every 10 seconds, the 0.1 Hz rhythm in LF power.
Baseline
Your own usual HRV level and range, built from weeks of readings taken the same way. Comparing a reading with your baseline says more than comparing it with other people.
Beat correction
Finding the beat intervals that are wrong (missed, extra or ectopic beats) and deleting or replacing them before HRV is calculated. The rule of thumb is to correct under 5% of beats.
Breathing rate
How many breaths you take a minute. It moves HRV on its own: slower, deeper breathing makes the beat-to-beat swing larger, and below about 9 breaths a minute it shifts from the HF band into LF.

C

Circadian rhythm
The body's 24-hour clock. Heart rate is lower and vagal HRV higher at night than by day, so readings are only comparable when they are taken at the same time of day.
Co-activation
Both branches of the autonomic nervous system rising, or falling, at the same time. They are not a seesaw, so one HRV number cannot place you on a single scale.
Coherence measured in ratio
A HeartMath score for how much of the HRV spectrum sits in one narrow peak between 0.04 and 0.26 Hz. Slow breathing at about 6 a minute produces it, so it largely measures breathing pace.

D

Deceleration capacity measured in ms
The average size of the heart's slow-downs, in milliseconds, found by averaging the pattern around every beat slower than the one before. A 24-hour vagal measure used after heart attacks.
Detrending
Removing the slow drift from a series of beat intervals before a spectrum is calculated, so the drift does not pile up as false power in the lowest frequencies.
DFA α1 measured in exponent
The short-term scaling exponent of detrended fluctuation analysis. Near 1 the beats have memory at every scale; near 0.5 they behave like noise. α2 is the same slope over longer stretches.

E

ECG
A recording of the heart's electrical activity, taken with electrodes on the skin. ECG-based RR intervals are the reference standard for measuring HRV.
Ectopic beat
A heartbeat that starts outside the heart's normal pacemaker and usually comes early. Ectopic beats are common, but they distort HRV unless removed or corrected.

H

Heart rate turbulence measured in % and ms/beat
The brief speed-up and slower recovery of the heart rhythm after a premature ventricular beat, measured from a 24-hour ECG as two numbers: turbulence onset (%) and turbulence slope (ms per beat).
Heart rate variability
The natural variation in time between one heartbeat and the next. It mostly reflects how the autonomic nervous system adjusts the heart from beat to beat.
HF power measured in ms²
The variance of the heartbeat intervals that falls in the 0.15 to 0.40 Hz band, in ms²: the range of normal breathing. It mainly reflects vagal activity when breathing is 9 to 24 breaths a minute.
HRV biofeedback
A breathing practice in which you watch your heart rate live and breathe slowly, often near 6 breaths a minute, to make the heart's rise and fall with each breath as large as possible.
HRV triangular index measured in ratio
The number of NN intervals in a recording divided by the height of the tallest bar of their histogram. A unitless geometric measure of overall variability that a few bad beats barely move.

L

LF power measured in ms²
The variance of the heartbeat intervals that falls in the 0.04 to 0.15 Hz band, in ms²: rhythms repeating every 7 to 25 seconds. Once read as sympathetic activity, which is now disputed.
LF/HF ratio measured in ratio
LF power divided by HF power, with no unit. It was proposed as a gauge of balance between the sympathetic and parasympathetic systems, but research shows it cannot measure that reliably.
lnRMSSD
The natural logarithm of RMSSD, with no unit. Taking the log evens out the spread of RMSSD values, which makes day-to-day changes easier to compare and analyse.

M

Mayer waves
Slow waves in blood pressure and heart rate, about one every 10 seconds (0.1 Hz), made by the delay in the blood-pressure reflex. They are the main rhythm in the LF band at rest.
Mean RR measured in ms
The average time between heartbeats in a recording, in milliseconds. Heart rate is the same number upside down: 60,000 divided by the mean RR.

N

NN interval measured in ms
An RR interval between two normal heartbeats, in milliseconds, after extra beats and measurement errors are removed. Most HRV metrics are calculated from NN intervals.
NN50 measured in count
The number of pairs of neighbouring NN intervals that differ by more than 50 milliseconds. Dividing it by the number of successive differences, one fewer than the intervals, gives pNN50.
Normalised units measured in nu
LF or HF power as a percentage of their sum (LF + HF), rather than in ms². The two always add up to 100, so they carry one piece of information between them.

O

Orthostatic test
A short morning test: lie or sit still for 2 minutes, then stand for 2 minutes, recording heart rate and HRV in both positions to see how your body handles standing up.

P

Parasympathetic nervous system
The "rest and digest" branch of the autonomic nervous system. It slows the heart, mainly through the vagus nerve, and drives most of the beat-to-beat variation in HRV.
Parasympathetic saturation
When the vagal brake is so strong, usually in very fit people with very slow resting heart rates, that the beat-to-beat swing shrinks. HRV then falls while vagal activity is rising.
Peak frequency measured in Hz
The frequency, in Hz, at which a band of the HRV spectrum has its highest power. The HF peak is usually the breathing rate; the LF peak is usually near 0.1 Hz.
pNN20 measured in %
The percentage of neighbouring NN intervals that differ by more than 20 milliseconds. A lower-threshold cousin of pNN50 that still moves in people whose beat-to-beat changes are small.
pNN50 measured in %
The percentage of neighbouring NN intervals that differ by more than 50 milliseconds. It tracks fast, vagally driven changes, like RMSSD, but as a share rather than a size.
Poincaré plot
A scatter plot of each heartbeat interval against the one after it, in milliseconds on both axes. The shape of the cloud of dots shows short-term and overall variability at a glance.
PPG
An optical method that shines light into the skin and detects the pulse of blood with each heartbeat. Most watches, rings and phone-camera apps use it to estimate HRV.
Pulse rate variability
Variation in the time between pulse beats, measured optically by watches, rings and phone cameras. It closely tracks HRV at rest but drifts from it during movement.

R

Readiness score
A single number, often out of 100, that a device builds from your HRV, resting heart rate, sleep and other inputs to suggest how ready you are for the day. The weighting is not published.
Respiratory sinus arrhythmia
The normal rise in heart rate as you breathe in and fall as you breathe out. It is driven by the vagus nerve and makes up much of resting HRV.
Resting heart rate measured in bpm
How many times your heart beats per minute while you are fully at rest. For adults it is usually 60 to 100 beats per minute, and lower in well-trained athletes.
RMSSD measured in ms
Root mean square of successive differences: an HRV metric built from how much each heartbeat interval differs from the next, in milliseconds. It mainly reflects vagal activity.
RR interval measured in ms
The time from one heartbeat to the next, measured in milliseconds between the R peaks of an ECG. HRV is calculated from a series of these intervals.

S

Sample entropy measured in nats
How unpredictable the heartbeat series is: minus the log of the chance that runs of beats that match also match one beat longer. Near 0 is a repeating pattern; 2 or more is close to random.
Sampling rate
How many times a second a sensor measures the signal, in hertz (Hz). It sets how precisely each beat can be timed: about ±1 ms at 1000 Hz, ±4 ms at 250 Hz and ±20 ms at a 25 Hz camera.
SD1 and SD2 measured in ms
Two measures of the spread of dots in a Poincaré plot, in milliseconds. SD1 is the width and tracks short-term variability, like RMSSD; SD2 is the length and tracks overall variability.
SDANN measured in ms
The standard deviation of the mean NN interval of each 5-minute segment of a 24-hour recording, in milliseconds. It measures the slow changes over a day and ignores everything faster.
SDNN measured in ms
The standard deviation of all NN intervals in a recording, in milliseconds. It measures overall variability, and its value depends strongly on how long the recording lasts.
SDNN index measured in ms
The mean of the SDNN of each 5-minute segment of a 24-hour recording, in milliseconds. It keeps the variability inside each segment and drops the slow drift between them.
SDSD measured in ms
The standard deviation of the differences between neighbouring NN intervals, in milliseconds. It is almost the same number as RMSSD and measures the same fast, beat-to-beat change.
Sinus node
The heart's natural pacemaker, a small patch of cells that starts every normal heartbeat. Left alone it fires about 100 times a minute; the vagus nerve holds it lower at rest.
Stationarity
The assumption that the rhythms in a recording stay the same from start to finish. Frequency measures such as LF and HF need it; a recording that changes partway through breaks it.
Sympathetic nervous system
The "fight or flight" branch of the autonomic nervous system. It speeds up the heart and makes it pump harder, but it acts too slowly to drive beat-to-beat HRV.

T

Tachogram
A line chart of heartbeat intervals in the order they happened, one point per beat, in milliseconds. It shows HRV as a wavy line instead of a single number.
TINN measured in ms
The width, in milliseconds, of the base of the triangle that best fits the histogram of NN intervals. A geometric measure of overall variability from 24-hour Holter analysis.
Total power measured in ms²
The sum of the power in every band of the spectrum, in ms²: the variance of the heartbeat intervals. For a 5-minute recording it is VLF + LF + HF; over 24 hours ULF is added.

U

ULF power measured in ms²
The variance of the heartbeat intervals below 0.003 Hz, in ms²: rhythms slower than one cycle every 5 minutes, including the day-night cycle. It can only be measured from a 24-hour recording.

V

Vagal tone
The ongoing influence of the vagus nerve on the heart, which slows it down. It is usually estimated from HRV measures such as RMSSD and HF power.
Vagus nerve
The main nerve of the parasympathetic nervous system, running from the brainstem to the heart, lungs and gut. Its fast signals to the heart drive most beat-to-beat HRV.
VLF power measured in ms²
The variance of the heartbeat intervals in the 0.003 to 0.04 Hz band, in ms²: rhythms repeating every 25 seconds to 5 minutes. It needs at least a 5-minute recording and is best read over 24 hours.