HRV glossary
Short definitions of the terms you meet in HRV apps and research. Each links to a fuller explanation.
See every HRV parameter grouped by family Units, formulas and recording lengths side by side, from RMSSD to DFA α1.
A
- Approximate entropy measured in nats
- The older cousin of sample entropy, with no unit: a regularity measure that counts each run of beats as matching itself, which biases it towards low values on short recordings.
- Artifact
- An error in a heartbeat recording, such as a missed, extra or mistimed beat, often caused by movement or poor sensor contact. Artifacts can badly distort HRV numbers.
- Autonomic nervous system
- The part of the nervous system that runs the body without conscious control, including heart rate. HRV mostly reflects how it adjusts the heart from moment to moment.
B
- Baevsky stress index measured in ratio
- A number built from the histogram of heartbeat intervals, with no unit. It rises as the rhythm gets steadier and less variable, which Baevsky read as strain on the body's regulation.
- Baroreflex
- The reflex that steadies blood pressure from beat to beat by changing heart rate. Its built-in delay makes heart rate rise and fall about every 10 seconds, the 0.1 Hz rhythm in LF power.
- Baseline
- Your own usual HRV level and range, built from weeks of readings taken the same way. Comparing a reading with your baseline says more than comparing it with other people.
- Beat correction
- Finding the beat intervals that are wrong (missed, extra or ectopic beats) and deleting or replacing them before HRV is calculated. The rule of thumb is to correct under 5% of beats.
- Breathing rate
- How many breaths you take a minute. It moves HRV on its own: slower, deeper breathing makes the beat-to-beat swing larger, and below about 9 breaths a minute it shifts from the HF band into LF.
C
- Circadian rhythm
- The body's 24-hour clock. Heart rate is lower and vagal HRV higher at night than by day, so readings are only comparable when they are taken at the same time of day.
- Co-activation
- Both branches of the autonomic nervous system rising, or falling, at the same time. They are not a seesaw, so one HRV number cannot place you on a single scale.
- Coherence measured in ratio
- A HeartMath score for how much of the HRV spectrum sits in one narrow peak between 0.04 and 0.26 Hz. Slow breathing at about 6 a minute produces it, so it largely measures breathing pace.
D
- Deceleration capacity measured in ms
- The average size of the heart's slow-downs, in milliseconds, found by averaging the pattern around every beat slower than the one before. A 24-hour vagal measure used after heart attacks.
- Detrending
- Removing the slow drift from a series of beat intervals before a spectrum is calculated, so the drift does not pile up as false power in the lowest frequencies.
- DFA α1 measured in exponent
- The short-term scaling exponent of detrended fluctuation analysis. Near 1 the beats have memory at every scale; near 0.5 they behave like noise. α2 is the same slope over longer stretches.
E
- ECG
- A recording of the heart's electrical activity, taken with electrodes on the skin. ECG-based RR intervals are the reference standard for measuring HRV.
- Ectopic beat
- A heartbeat that starts outside the heart's normal pacemaker and usually comes early. Ectopic beats are common, but they distort HRV unless removed or corrected.
H
- Heart rate turbulence measured in % and ms/beat
- The brief speed-up and slower recovery of the heart rhythm after a premature ventricular beat, measured from a 24-hour ECG as two numbers: turbulence onset (%) and turbulence slope (ms per beat).
- Heart rate variability
- The natural variation in time between one heartbeat and the next. It mostly reflects how the autonomic nervous system adjusts the heart from beat to beat.
- HF power measured in ms²
- The variance of the heartbeat intervals that falls in the 0.15 to 0.40 Hz band, in ms²: the range of normal breathing. It mainly reflects vagal activity when breathing is 9 to 24 breaths a minute.
- HRV biofeedback
- A breathing practice in which you watch your heart rate live and breathe slowly, often near 6 breaths a minute, to make the heart's rise and fall with each breath as large as possible.
- HRV triangular index measured in ratio
- The number of NN intervals in a recording divided by the height of the tallest bar of their histogram. A unitless geometric measure of overall variability that a few bad beats barely move.
L
- LF power measured in ms²
- The variance of the heartbeat intervals that falls in the 0.04 to 0.15 Hz band, in ms²: rhythms repeating every 7 to 25 seconds. Once read as sympathetic activity, which is now disputed.
- LF/HF ratio measured in ratio
- LF power divided by HF power, with no unit. It was proposed as a gauge of balance between the sympathetic and parasympathetic systems, but research shows it cannot measure that reliably.
- lnRMSSD
- The natural logarithm of RMSSD, with no unit. Taking the log evens out the spread of RMSSD values, which makes day-to-day changes easier to compare and analyse.
M
- Mayer waves
- Slow waves in blood pressure and heart rate, about one every 10 seconds (0.1 Hz), made by the delay in the blood-pressure reflex. They are the main rhythm in the LF band at rest.
- Mean RR measured in ms
- The average time between heartbeats in a recording, in milliseconds. Heart rate is the same number upside down: 60,000 divided by the mean RR.
N
- NN interval measured in ms
- An RR interval between two normal heartbeats, in milliseconds, after extra beats and measurement errors are removed. Most HRV metrics are calculated from NN intervals.
- NN50 measured in count
- The number of pairs of neighbouring NN intervals that differ by more than 50 milliseconds. Dividing it by the number of successive differences, one fewer than the intervals, gives pNN50.
- Normalised units measured in nu
- LF or HF power as a percentage of their sum (LF + HF), rather than in ms². The two always add up to 100, so they carry one piece of information between them.
O
- Orthostatic test
- A short morning test: lie or sit still for 2 minutes, then stand for 2 minutes, recording heart rate and HRV in both positions to see how your body handles standing up.
P
- Parasympathetic nervous system
- The "rest and digest" branch of the autonomic nervous system. It slows the heart, mainly through the vagus nerve, and drives most of the beat-to-beat variation in HRV.
- Parasympathetic saturation
- When the vagal brake is so strong, usually in very fit people with very slow resting heart rates, that the beat-to-beat swing shrinks. HRV then falls while vagal activity is rising.
- Peak frequency measured in Hz
- The frequency, in Hz, at which a band of the HRV spectrum has its highest power. The HF peak is usually the breathing rate; the LF peak is usually near 0.1 Hz.
- pNN20 measured in %
- The percentage of neighbouring NN intervals that differ by more than 20 milliseconds. A lower-threshold cousin of pNN50 that still moves in people whose beat-to-beat changes are small.
- pNN50 measured in %
- The percentage of neighbouring NN intervals that differ by more than 50 milliseconds. It tracks fast, vagally driven changes, like RMSSD, but as a share rather than a size.
- Poincaré plot
- A scatter plot of each heartbeat interval against the one after it, in milliseconds on both axes. The shape of the cloud of dots shows short-term and overall variability at a glance.
- PPG
- An optical method that shines light into the skin and detects the pulse of blood with each heartbeat. Most watches, rings and phone-camera apps use it to estimate HRV.
- Pulse rate variability
- Variation in the time between pulse beats, measured optically by watches, rings and phone cameras. It closely tracks HRV at rest but drifts from it during movement.
R
- Readiness score
- A single number, often out of 100, that a device builds from your HRV, resting heart rate, sleep and other inputs to suggest how ready you are for the day. The weighting is not published.
- Respiratory sinus arrhythmia
- The normal rise in heart rate as you breathe in and fall as you breathe out. It is driven by the vagus nerve and makes up much of resting HRV.
- Resting heart rate measured in bpm
- How many times your heart beats per minute while you are fully at rest. For adults it is usually 60 to 100 beats per minute, and lower in well-trained athletes.
- RMSSD measured in ms
- Root mean square of successive differences: an HRV metric built from how much each heartbeat interval differs from the next, in milliseconds. It mainly reflects vagal activity.
- RR interval measured in ms
- The time from one heartbeat to the next, measured in milliseconds between the R peaks of an ECG. HRV is calculated from a series of these intervals.
S
- Sample entropy measured in nats
- How unpredictable the heartbeat series is: minus the log of the chance that runs of beats that match also match one beat longer. Near 0 is a repeating pattern; 2 or more is close to random.
- Sampling rate
- How many times a second a sensor measures the signal, in hertz (Hz). It sets how precisely each beat can be timed: about ±1 ms at 1000 Hz, ±4 ms at 250 Hz and ±20 ms at a 25 Hz camera.
- SD1 and SD2 measured in ms
- Two measures of the spread of dots in a Poincaré plot, in milliseconds. SD1 is the width and tracks short-term variability, like RMSSD; SD2 is the length and tracks overall variability.
- SDANN measured in ms
- The standard deviation of the mean NN interval of each 5-minute segment of a 24-hour recording, in milliseconds. It measures the slow changes over a day and ignores everything faster.
- SDNN measured in ms
- The standard deviation of all NN intervals in a recording, in milliseconds. It measures overall variability, and its value depends strongly on how long the recording lasts.
- SDNN index measured in ms
- The mean of the SDNN of each 5-minute segment of a 24-hour recording, in milliseconds. It keeps the variability inside each segment and drops the slow drift between them.
- SDSD measured in ms
- The standard deviation of the differences between neighbouring NN intervals, in milliseconds. It is almost the same number as RMSSD and measures the same fast, beat-to-beat change.
- Sinus node
- The heart's natural pacemaker, a small patch of cells that starts every normal heartbeat. Left alone it fires about 100 times a minute; the vagus nerve holds it lower at rest.
- Stationarity
- The assumption that the rhythms in a recording stay the same from start to finish. Frequency measures such as LF and HF need it; a recording that changes partway through breaks it.
- Sympathetic nervous system
- The "fight or flight" branch of the autonomic nervous system. It speeds up the heart and makes it pump harder, but it acts too slowly to drive beat-to-beat HRV.
T
- Tachogram
- A line chart of heartbeat intervals in the order they happened, one point per beat, in milliseconds. It shows HRV as a wavy line instead of a single number.
- TINN measured in ms
- The width, in milliseconds, of the base of the triangle that best fits the histogram of NN intervals. A geometric measure of overall variability from 24-hour Holter analysis.
- Total power measured in ms²
- The sum of the power in every band of the spectrum, in ms²: the variance of the heartbeat intervals. For a 5-minute recording it is VLF + LF + HF; over 24 hours ULF is added.
U
- ULF power measured in ms²
- The variance of the heartbeat intervals below 0.003 Hz, in ms²: rhythms slower than one cycle every 5 minutes, including the day-night cycle. It can only be measured from a 24-hour recording.
V
- Vagal tone
- The ongoing influence of the vagus nerve on the heart, which slows it down. It is usually estimated from HRV measures such as RMSSD and HF power.
- Vagus nerve
- The main nerve of the parasympathetic nervous system, running from the brainstem to the heart, lungs and gut. Its fast signals to the heart drive most beat-to-beat HRV.
- VLF power measured in ms²
- The variance of the heartbeat intervals in the 0.003 to 0.04 Hz band, in ms²: rhythms repeating every 25 seconds to 5 minutes. It needs at least a 5-minute recording and is best read over 24 hours.