NN interval

Also called NN intervals, normal-to-normal interval

An RR interval between two normal heartbeats, in milliseconds, after extra beats and measurement errors are removed. Most HRV metrics are calculated from NN intervals.

Unit: ms

An NN interval is the time between two normal heartbeats, in milliseconds. NN stands for normal-to-normal.

Why the term exists

The 1996 Task Force defines NN intervals as the gaps between neighbouring beats that both start in the sinus node Sinus node The heart's natural pacemaker, a small patch of cells that starts every normal heartbeat. Left alone it fires about 100 times a minute; the vagus nerve holds it lower at rest. More about Sinus node , the heart’s built-in pacemaker. Only those beats carry the nervous system’s signal. An ectopic beat Ectopic beat A heartbeat that starts outside the heart's normal pacemaker and usually comes early. Ectopic beats are common, but they distort HRV unless removed or corrected. More about Ectopic beat starts somewhere else in the heart, arrives early and is often followed by a longer pause; a loose electrode or a movement makes a sensor miss a beat or count one twice. Each leaves an interval much too short or much too long, and every HRV measure that squares differences treats such an interval as a huge change. The Task Force’s rule is that the measures are computed from NN intervals: the RR intervals RR interval The time from one heartbeat to the next, measured in milliseconds between the R peaks of an ECG. HRV is calculated from a series of these intervals. More about RR interval left once the odd ones have been removed or corrected.

How the cleaning works

NN={RRi:both beats are sinus beats}\mathrm{NN} = \left\{\mathrm{RR}_i : \text{both beats are sinus beats}\right\}

In practice a program flags intervals that differ too much from their neighbours or from a running median, then deletes them or replaces them with an estimate (the mean of the neighbours, a straight line, or a smooth curve through them). Peltola’s 2012 review shows that each method shifts the result, and that short recordings are the most sensitive: in a few minutes of beats, editing even fewer than 5 % of the intervals can change the measures, while a 24-hour recording tolerates far more.

Worked example

Each beat against the next

Five minutes of the teaching recording

SD1 (across)
23.6 ms
SD2 (along)
33.1 ms
SD1/SD2
0.71
RMSSD
33.4 ms
SDNN
28.7 ms

The cloud is 1.4 times longer than it is wide: SD1 23.6 ms across the diagonal (fast change), SD2 33.1 ms along it (slow and fast change together).

The sliders and the button work when JavaScript is on.

Every interval of the teaching recording plotted against the one after it. The cloud's width across the diagonal is SD1 (fast, beat-to-beat change) and its length along the diagonal is SD2 (slow and fast change together). Move the sliders to change each kind of swing, or add one premature beat and watch SD1 jump.

A square scatter plot with the previous interval across and the next interval up, both in milliseconds and zoomed on the cloud, a diagonal line of identity and an ellipse tilted along it. Readouts give SD1, SD2, their ratio, RMSSD and SDNN, followed by a sentence explaining the shape. Two sliders set the size of the beat-to-beat swing and of the slow swings; a button adds one premature beat, and the readout then also shows SD1 and SD2 from before it.

Five minutes of the teaching recording are all normal beats: the cloud is 33.1 ms long and 23.6 ms wide. Press “Add an ectopic beat”: one premature beat and its pause make two intervals that are not NN intervals, their dots land far from the cloud, and SD1 SD1 and SD2 Two measures of the spread of dots in a Poincaré plot, in milliseconds. SD1 is the width and tracks short-term variability, like RMSSD; SD2 is the length and tracks overall variability. More about SD1 and SD2 (which is RMSSD RMSSD Root mean square of successive differences: an HRV metric built from how much each heartbeat interval differs from the next, in milliseconds. It mainly reflects vagal activity. More about RMSSD divided by the square root of two) jumps from 23.6 to 39.8 ms. Removing that one beat is the difference between the two numbers.

What moves it

Nothing moves the NN intervals that does not move the RR intervals; the difference is which intervals are kept. The share removed is the thing to watch, because in a short recording even a few edited beats can change the result.

When it misleads

When the cleaning is too loose, a premature beat survives and inflates every beat-to-beat measure. When it is too strict, real fast changes are cut out as “ artifacts Artifact An error in a heartbeat recording, such as a missed, extra or mistimed beat, often caused by movement or poor sensor contact. Artifacts can badly distort HRV numbers. More about Artifact ” and RMSSD falls. Two programs with different rules give different numbers from the same beats, and an app that reports “artifacts: 3 %” without saying what it did with them has told you half the story.

Where you will see it

The Task Force’s tables are written in NN intervals: SDNN SDNN The standard deviation of all NN intervals in a recording, in milliseconds. It measures overall variability, and its value depends strongly on how long the recording lasts. More about SDNN , NN50 NN50 The number of pairs of neighbouring NN intervals that differ by more than 50 milliseconds. Dividing it by the number of successive differences, one fewer than the intervals, gives pNN50. More about NN50 , pNN50 pNN50 The percentage of neighbouring NN intervals that differ by more than 50 milliseconds. It tracks fast, vagally driven changes, like RMSSD, but as a share rather than a size. More about pNN50 and TINN TINN The width, in milliseconds, of the base of the triangle that best fits the histogram of NN intervals. A geometric measure of overall variability from 24-hour Holter analysis. More about TINN all carry the letters. Kubios HRV calls its cleaning “ beat correction Beat correction Finding the beat intervals that are wrong (missed, extra or ectopic beats) and deleting or replacing them before HRV is calculated. The rule of thumb is to correct under 5% of beats. More about Beat correction ” and reports how many beats it changed; apps show an artifact percentage or a signal-quality label. The lesson How HRV is measured: from beats to a number shows where this cleaning step fits.

Sources

  1. Heart rate variability: standards of measurement, physiological interpretation and clinical use Circulation (Task Force of the ESC and NASPE), 1996
  2. Role of editing of R-R intervals in the analysis of heart rate variability Frontiers in Physiology, 2012

All glossary terms

All HRV parameters