HF power
Also called HF, high-frequency power, high frequency band, respiratory band
The variance of the heartbeat intervals that falls in the 0.15 to 0.40 Hz band, in ms²: the range of normal breathing. It mainly reflects vagal activity when breathing is 9 to 24 breaths a minute.
Unit: ms²
HF power is the amount of heartbeat-interval variance that falls between 0.15 and 0.40 Hz, in ms². That band matches breathing at 9 to 24 breaths a minute, which is why it is also called the respiratory band.
Why this measure exists
Most of the fast variation in a resting heart is respiratory sinus arrhythmia Respiratory sinus arrhythmia The normal rise in heart rate as you breathe in and fall as you breathe out. It is driven by the vagus nerve and makes up much of resting HRV. More about Respiratory sinus arrhythmia : the heart speeds up a little on each in-breath and slows on each out-breath, under the control of the vagus nerve Vagus nerve The main nerve of the parasympathetic nervous system, running from the brainstem to the heart, lungs and gut. Its fast signals to the heart drive most beat-to-beat HRV. More about Vagus nerve . The 1996 Task Force drew the HF band around normal breathing rates so that one number would capture that rhythm. Experiments that blocked or stimulated the vagus nerve showed the band tracks vagal activity Vagal tone The ongoing influence of the vagus nerve on the heart, which slows it down. It is usually estimated from HRV measures such as RMSSD and HF power. More about Vagal tone , and researchers use HF power, with RMSSD RMSSD Root mean square of successive differences: an HRV metric built from how much each heartbeat interval differs from the next, in milliseconds. It mainly reflects vagal activity. More about RMSSD , as the frequency-domain index of vagal tone.
The formula
Add up the power spectral density , in ms² per Hz, over every frequency from 0.15 to 0.40 Hz. is the spectrum of the interval series after resampling and detrending Detrending Removing the slow drift from a series of beat intervals before a spectrum is calculated, so the drift does not pile up as false power in the lowest frequencies. More about Detrending , usually by Welch’s method. The result is a variance, in ms².
Worked example
Take the rhythm apart
Five minutes of the teaching recording
- ULF
- needs 24 h
- VLF
- 3 ms²
- LF
- 120 ms²
- HF
- 635 ms²
- Total
- 758 ms²
- LF nu
- 15.9
- HF nu
- 84.1
- LF/HF
- 0.19
- Peak
- 0.250 Hz, HF
Rested, 15 breaths a minute (0.250 Hz), 5 minutes, Welch's method after detrending. The breathing peak sits at 0.250 Hz in the HF band, with the ~0.1 Hz blood-pressure wave as a smaller LF peak. LF/HF is 0.19.
The controls work when JavaScript is on.
A line chart of power against frequency from 0 to 0.5 Hz with the VLF (0.003–0.04 Hz), LF (0.04–0.15 Hz) and HF (0.15–0.4 Hz) bands shaded and a marker at the breathing frequency. Readouts give ULF, VLF, LF, HF and total power in ms squared, LF and HF in normalised units, the LF/HF ratio and the peak frequency, followed by a sentence explaining what changed. Controls: a breathing-rate slider from 5 to 20 breaths a minute, a recording-length slider, a detrending checkbox, Welch or Lomb–Scargle buttons, and four preset buttons for a rested, stressed, drifting or ectopic recording.
The five minutes of the teaching recording, breathing at 15 a minute, put the breathing peak at 0.250 Hz and give an HF power of 635 ms², 84.1 % of LF LF power The variance of the heartbeat intervals that falls in the 0.04 to 0.15 Hz band, in ms²: rhythms repeating every 7 to 25 seconds. Once read as sympathetic activity, which is now disputed. More about LF power + HF. Slow the breathing to 7 a minute and HF collapses to 19 ms² while LF swells, because the same breathing rhythm has crossed the 0.15 Hz line. Switch the recording length to 60 seconds: HF is still readable, because its slowest cycle takes under 7 seconds.
What moves it
Vagal activity, and breathing. Deeper breaths make the rhythm bigger and raise HF without any change in the nervous system; slower breaths move the rhythm out of the band. It falls with age, standing, alcohol, illness and mental stress, and rises in sleep. Laborde and colleagues’ guidelines recommend monitoring breathing during recordings. The Task Force’s table gives 975 ± 203 ms² for a stationary Stationarity The assumption that the rhythms in a recording stay the same from start to finish. Frequency measures such as LF and HF need it; a recording that changes partway through breaks it. More about Stationarity supine 5-minute recording, a value it calls approximate; Nunan and colleagues’ pooled short-term mean is 657 ms² with a very wide spread; and HF needs about 1 minute of recording.
When it misleads
Outside the 9 to 24 range the band no longer holds the breathing rhythm. A person breathing at 6 a minute shows a tiny HF power and a huge LF power while deeply relaxed. A sharp artifact Artifact An error in a heartbeat recording, such as a missed, extra or mistimed beat, often caused by movement or poor sensor contact. Artifacts can badly distort HRV numbers. More about Artifact adds power to every band but mostly here. Absolute HF is heavily skewed between people, so papers report its log or its normalised share, and a day-to-day change in your own HF is more readable than one value. RMSSD, its time-domain partner, also changes with breathing, but it does not depend on where the breathing peak falls relative to a band edge, and it is the number most wearables report.
Where you will see it
The Task Force’s name is HF, in ms² and in normalised units Normalised units LF or HF power as a percentage of their sum (LF + HF), rather than in ms². The two always add up to 100, so they carry one piece of information between them. More about Normalised units . Kubios HRV prints the HF peak Peak frequency The frequency, in Hz, at which a band of the HRV spectrum has its highest power. The HF peak is usually the breathing rate; the LF peak is usually near 0.1 Hz. More about Peak frequency frequency, absolute power, its log, relative power and n.u.; Elite HRV shows HF in ms² and says HF can be measured from 60 seconds. What do LF, HF, VLF and nu mean in my HRV app? decodes a typical app screen.
Sources
- Heart rate variability: standards of measurement, physiological interpretation and clinical use
- An overview of heart rate variability metrics and norms
- Heart rate variability and cardiac vagal tone in psychophysiological research: recommendations for experiment planning, data analysis, and data reporting
- What are HRV frequency measurements (LF, HF, LF/HF)